12
General CommentsInspection conducted with CPO Mike Henson. Issues from previous inspection corrected. Verified the following for updated in-field plan review: Electrical permit E4638297 passed inspection 6-4-2024. Pentair Intelliflo 3 011068 1.5 HP pump TR-50 filter 4x returns 1 skimmer with EQ line plugged per state guidelines 1.5” piping for skimmer, main drain, and return 4x Aquastar WAV9WRxxx 2017 drain covers Permit issued with the following conditions No Night Swimming Flow meter must remain operable. Flow shall be kept at 10 GPM to 49 GPM to meet turnover and flow restriction of filter.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No New log sheets provided for wading but, but no Total Alkalinity or Cyanuric Acid check for pool or wading pool for July. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Operator took readings for pool and wading today.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Non-functioning gate with plexiglass installed, creating new horizontals in the fencing. .2528(b) Pre-2010 horizontals shall not be located less than 30" in height.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No No labeling on new piping. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.