Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCEDARFIELD II
Address8873 STRATTON FARM ROAD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 7/8/2024
Final Score @ Grade
24
General CommentsPre-permit and in-field plan review inspection conducted with CPO Mike Henson. 911 has 8801 Stratton Farm Rd. Correct address is 8873 Stratton Farm Rd. Follow up with phone company to correct. Electrical permit E4638297 passed inspection 6-4-2024. In-Field Plan review did not pass. Observed the following: Pentair Intelliflo 3 011068 1.5 HP pump TR-50 filter 4x returns 1 skimmer with EQ line plugged per state guidelines 1.5” piping for skimmer, main drain, and return 4x Aquastar WAV9WRxxx 2017 drain covers Pre-permit inspection did not pass In-field plan review 5) 8) 16) 22) There is a $100 re-inspection fee that must be paid by calling our office (980) 314-1620 and paying with a credit card prior to scheduling a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log sheet does not provide separate areas for pool and wading main drain, Total alkalinity, and cyanuric acid checks. No records for total alkalinity, cyanuric acid, or main drains for wading pool. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer basket too big to properly fit in the skimmer. Top above the water line. .2518(k) Provide functional skimmer basket designed for this skimmer. - Corrected. Weir not fully installed, stuck in skimmer throat. .2518(k) Provide functional weirs. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One wading pool gate stuck. Not able to test. .2531(a) Wading pool gates shall open away from the swimming pool and be self-closing and self-latching. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No No lifeguard on duty sign not posted in wading pool area. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Pre-permit item.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No No labeling on new piping. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.