5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.- Observed expired chemical test kit. Obtain a new and up to date test kit. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.- Observed ring buoy rope length measured at 40ft. Provide required rope length at 45ft. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).- Observed at the bottom space of the fence in some area measured up 5.5”. The bottom space needs to be corrected to be 2” or less.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.- Observed fencing at the front near the gate with foot holes along the edge on the outside measured less than 48”. Fix the foot holes and provide at least 48” in height fencing all around.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".- Observed an opening between the fence and the building wall leaving space measured about 6”. Issue need to be fixed. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.- Observed deep cracks cement on pool deck around edge of the pool need repair. Keep deck surfaces in good repair. |