Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLEGACY CORNELIUS
Address8335 LAKE PINES DR
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/22/2020
Final Score @ Grade
34
General CommentsInspection conducted with Eddy Dixon. Due to COVID-19 precautions, inspection was not signed by the operator. Contact Will Harrison (704-507-6824) to field verify items when they have been fixed. Permit issued. No night swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No One screw missing from each of the main drains. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7 and installed per manufacturer's instructions. Will verify completion next week.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Plaster etching on sunshelf. Operator plans to replaster before next year.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 4" depth marker in the shallow end of the pool. .2523(c) Depth markers shall include the word "feet" or symbol "ft". This will need to be corrected prior to 2021 operational permit being issued.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope too long. .2530(a) Provide USCG approved ring buoy with 33 foot throw rope. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magnetic gate latches < 45", creating a foothold. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Operator will install 45 degree angled metal to be verified next week. Thumbscrews removed from windows in fitness center and some of the windows in the clubhouse. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Will verify next week.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Corrected. Holes in the deck from missing lift. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator will install the lift prior to opening the pool.
22 6 Premises: emergency telephone provided No No No Incorrect phone number posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected.