Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARBOR VILLAGE APARTMENT HOMES
Address839 SHADOW ELM DR
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/28/2026
Final Score @ Grade
32
General CommentsPERMIT DENIED. POOL IS NOT PERMITTED FOR NIGHT SWIMMING. PERMIT RESTRICTIONS: PERMIT RESTRICTION - FLOWVIS FLOW METER INSTALLED FOR DESIGN FLOW - MUST READ 103 GPM DUE TO TURNOVER

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH measuring 7.1 according to test kit. PERMIT DENIED.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2537(7) Drain covers shall be in good condition and securely attached. Observed both main drains missing all screws and had one screw in each securing covers down that were not in screw hole. Replace missing screws to secure covers. PERMIT DENIED. 2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed one equalizer cover missing. Hole was plugged with a vacuum line cover. Submit new PDSC form with new equalizer covers due to the 2008 6HPHAs no longer being produced. PERMIT DENIED. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed one 2017 Aqua star 6HPHA equalizer cover installed. PDSC states that they are supposed to be 2008 Aquastar 6HPHA covers. Replace with new equalizer covers on all 4 equalizer lines and submit a new PDSC form to Health department for approval that states their manufacturer, model and year. PERMIT DENIED. .
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed 4 pool wall depth markers with “4 1/2” on tile with FT missing from tile. Replace or repair tiles to include “FT” on all insufficient depth markers. PERMIT DENIED.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed styrofoam ring buoy without coast guard approval stamping or specs. Replace with a US Coast Guard approved ring buoy. PERMIT DENIED.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 (b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010). Observed rock retaining wall outside of pool fence that measures less than 30 inches to the next pool fence horizontal. Pool built prior to May 1, 2010. No permit action for this item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter not operating properly and maxing out. Unable to read true flow measurement. Repair or replace flow meter. PERMIT DENIED. Pool has the following permit restriction: PERMIT RESTRICTION - FLOWVIS FLOW METER INSTALLED FOR DESIGN FLOW - MUST READ 103 GPM DUE TO TURNOVER.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping in pump room without labels or color coding for direction of flow.