General CommentsInspection accompanied by CPO, John Darby. Must provide documentation of drain cover replacements within 30 days. Stated to have been. Replaced prior to start of last season (2025), according to CPO. Field verification conducted. No AutoChlor/interlock system used. All violations corrected during inspection. Night swimming requested; await confirmation from EHS to begin allowing guests to swim after dark. An evening/early morning visit will be made to verify proper lighting. EHS will follow up with CPO.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH 6.8 at start of inspection. Corrected- Bi-carb added to pool increased pH to 7.4 within an hour.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed substantial leaf litter in skimmer baskets. Corrected- CPO empties baskets before returning to skimmer.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Observed steps into pool with missing handrail and 1 inch deep holes in cement where hardware was removed, creating trip/injury hazard. Corrected- CPO reinstalls handrail. EHS advised returning hardware as soon as deck maintenance is finished, going forward. .2521 Install ladders per manufacturer instructions. Observed one missing ladder, removed for maintenance. Corrected- CPO properly reinstalls ladder.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate onto pool deck no self-closing. Corrected- CPO adjusts hinges and door self-closes, self latches.