NameDORAL APARTMENTS
Address554 BRAMLET RD
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2026
Final Score @ Grade
34
General CommentsPOOL IS NOT PERMITTED FOR NIGHT SWIMMING. FLOW METER MEASUREMENT: 100 GPM After discussion with Senior K. Rudisill, drain covers match PDSC form and are confirmed to be 2008 Lawson MLDFGD1212.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.1 according to EHS test kit. CDI: CPO raised pH to 7.3 by end of inspection.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed rusted screws one of the drain covers. CDI: CPO replaced with new stainless steel screws by end of inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope over 37FT in length. CDI: CPO adjusted rope to be 37FT.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed latch less than 54” with key pad no in use and gate able to be opened with latch only. CDI: CPO replaced batteries in key pad and gate now latches and locks with key pad in use.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed some cracking in deck on far side of pool. Repair.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Sign posted next to emergency phone observed lacking location’s address to emergency phone. - CDI - CPO wrote in address on sign in permanent marker. REPEAT
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap or soap dispenser in restroom. .2526(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper in restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed toilet and sink in need of cleaning.