Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed feature pump for bubblers as a Pentair intelliflo vs 011013. PDSC form states it is a Pentair intelliflo VS 011018. Provide updated PDSC form. PERMIT DENIED. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing return cover. CPO placed return cover on |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate closest to basketball court NOT self latching. Permit denied
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed audible alarm for door closest to restroom not operating. Door does not self latch. Permit denied |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deck drains sticking up. Permit denied. |