NameVISTA COMMONS APTS
Address2728 COMMONWEALTH AVE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/23/2019
Final Score @ Grade
12
General CommentsPDSC form was reviewed and verified. CPO was present during inspection. #11. Repair the small circular portion of the bottom step at the shallow end where the previous ladder rail was installed and made a slightly rough spot. This needs to be repaired by next pool inspection for safety of patrons.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. CPO provided test kit with reagents expiring recently. CPO to obtain new test kit.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed missing plastic cap on ladder leg.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed gate not self-latching when opened halfway. CDI. CPO was able to repair during the inspection and gate self-closed and self-latched appropriately.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backflow prevention device on hose bibb at pool deck.