6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC form incorrect. 12MFxxx drain covers installed. Corrected during inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed >6" from pool wall to ladder rung on multiple ladders. Maintain 3" to 6" between pool wall and ladder rung. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed 42" from brick to top of fence at building. Maintain 45" or more between horizontals. Pool was built in 1966.
Decorative gate with decorative cut-outs exceeding 1.75". Gate is original to the property and was not caught on previous inspection. Given 1 week to correct.
.2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches.
.2528(a) Diagonal members on fence and/or gate shall not exceed 1.75 inches. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Fill line cover with offset >1". Corrected with cement during inspection. |