Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHEATHERSTONE II
Address9255 MEADOW VISTA RD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/25/2026
Final Score @ Grade
52
General CommentsNotes: - (1) of 2 gates permanently disabled. Per building code and fire code, 2 gates may be required. Recommend verifying with other trades to ensure second gate can remain permanently disabled. - Hose bib in chemical storage room. Per code enforcement, water supply should not be provided in areas where chemicals are stored. Permit Denied for the following: .2535 - maintain pH at 7.2 to 7.8. .2539 - replace rusted screws in equalizer line covers. .2518 - replace skimmer weir - maintain water level so skimmers functional. .2521 - contrasting color band on steps shall be 2x2 tile .2528 - repair gate to 2" or less underneath and repair meshing to eliminate hazard. .2537 - repair coping at deck and coping closest to pump so offset less than 1/2". .2518 - repair pressure gauge on filter. Matt Yates present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 7.0. Maintain at 7.2 to 7.8. Permit denied.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Screws rusted in equalizer line covers on wall. Screws shall be stainless. Replace so secured. Permit denial.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some chipping plaster. Plaster areas where chipped are not sharp and do not appear to present hazard. Plaster shall require repair if worsens.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer without weir closest to steps. Replace weir. Permit denial. Water level low. Pool appears to have a leak. Operator stated they are consistently having to add water. Water level shall be maintained so that skimmers are operable. Permit denial.
13 4 Pool maintenance: contrasting band on steps and benches No No No Pool putty in multiple locations on steps where contrasting tile is covered and not 2" thick. Repair contrasting color band so 2" thick per rule. Permit denial.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring for buoy too long. Cut to 38 ft. during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >2" under gate. Maintain 2" or less on gate. Permit denial. Damage to meshing on front gate - presents hazard to public due to the metal. Repair. Meshing required due to support beam on gate. Permit denial. Multiple areas of fence >4" from ground to bottom horizontal. Pool built in 2008.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No >1/2" offset between coping and deck at area closest to pump room. 1/2" between coping and deck opposite side of pool also. Permit denial for coping >1/2".
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on 300-29x feeder. Additional feeder in place but lid broken and not in use. Chlorinator shall be NSF approved. Install flow meter on chlorinator.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pressure gauge not operable on filter. Repair pressure gauge. Permit denial.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No shelving in chemical storage room to maintain pool chemicals up off the floor. Provide shelving to keep chemicals stored up off the floor. Light burnt out in chemical storage room. Repair light. Dry chemicals in tub in pump room. Store chemicals in approved chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels/hand soap in restrooms. Provide. Restrooms with debris/in need of cleaning. Keep clean.