| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Maintain at 7.2 to 7.8. Permit denied. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Screws rusted in equalizer line covers on wall. Screws shall be stainless. Replace so secured. Permit denial. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some chipping plaster. Plaster areas where chipped are not sharp and do not appear to present hazard. Plaster shall require repair if worsens. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer without weir closest to steps. Replace weir. Permit denial.
Water level low. Pool appears to have a leak. Operator stated they are consistently having to add water. Water level shall be maintained so that skimmers are operable. Permit denial. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Pool putty in multiple locations on steps where contrasting tile is covered and not 2" thick. Repair contrasting color band so 2" thick per rule. Permit denial. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring for buoy too long. Cut to 38 ft. during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
>2" under gate. Maintain 2" or less on gate. Permit denial.
Damage to meshing on front gate - presents hazard to public due to the metal. Repair. Meshing required due to support beam on gate. Permit denial.
Multiple areas of fence >4" from ground to bottom horizontal. Pool built in 2008. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
>1/2" offset between coping and deck at area closest to pump room. 1/2" between coping and deck opposite side of pool also. Permit denial for coping >1/2". |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on 300-29x feeder. Additional feeder in place but lid broken and not in use. Chlorinator shall be NSF approved. Install flow meter on chlorinator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pressure gauge not operable on filter. Repair pressure gauge. Permit denial. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No shelving in chemical storage room to maintain pool chemicals up off the floor. Provide shelving to keep chemicals stored up off the floor.
Light burnt out in chemical storage room. Repair light.
Dry chemicals in tub in pump room. Store chemicals in approved chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No paper towels/hand soap in restrooms. Provide.
Restrooms with debris/in need of cleaning. Keep clean. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Some hose bibs without backflow prevention device. Provide backflow preventers on all hose bibs. |