Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed PDSC form showing the equalizers are permanently disabled per state recommendations. EHS observed equalizer covers still on the side of the pool and open equalizer lines inside the skimmer. CPO permanently disabled all equalizers during inspection.
NC G.S 130A 2(3): EHS observed bonding wire that is attached to the pump snapped in half. Bonding wire was repaired during inspection. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 30ft, CPO cut ring buoy rope to required length during inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. 911 operator stated the address that was on file is 1003 E Woodlawn, signage and MCHD paperwork state the address is 1006E Woodlawn. Operator has one week to remedy this violation or the permit will be suspended. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2519(k) Provide operational pressure gauge on filter. Observed pressure gauge on filter not operational. CPO repaired pressure gauge during inspection. |