| Name | CENTRAL PARK AT AYRSLEY | | Address | 2340 RACHELWOOD DR
| | | | City/State/ZIP | | | Premise Type | 50 - Seasonal Swimming Pool | | County | Mecklenburg | | Inspection Date
| 4/28/2025 | | Final Score @ Grade | | | No night swimming.
Pump Hayward SP32950VSP
Main Drain Aquastar 12MFxxx VGBA2017 x2
Equalizers Aquastar 6HPHAxxx VGBA 2017 x4
Pipe Sizes
Skimmer 3” - Skimmer line is 4 inches
Main Drain 4”
Return 3” - Return line is 4 inches
Permit Restriction - Pump must be set at 3450 rpm -or- flow must be at least 104gpm
for turnover and cannot exceed 141gpm for filter limitation with a properly installed and
operational flow meter.
In field plan review completed during inspection. Only change is size of skimmer and return lines. |
|