16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed two sections of fence with a 6" gap under
fence from where ground has eroded away. CDI: Operator built up ground around areas mentioned using rocks and pine needles to
reduce gap to 2". |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed flow meter stuck and reading 0 during inspection. CDI: Flow meter repaired. (Pool was too full and returns were not functioning properly. Issue resolved.)
.2519(k) Provide operational pressure gauge on filter. Observed effluent pressure gauge at 0 during inspection. CDI: When return line was fixed, pressure gauge began reading properly. |