Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVILLAGES AT BACK CREEK
Address9808 HANBERRY BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/19/2024
Final Score @ Grade
20
General CommentsObserved the following items for infield plan review verification Pump - Hayward HCP30703 Main Drains - Aquastar 12MFxxx Returns - 16 Skimmers - 8 Filters - 2xTR140C Infield plan review complete Permit restriction: VFD must remain at 60hz. Pump is approved on design flow.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed several skimmer weirs stuck. .2518(k) Surface skimmers shall be installed per manufacturer's instructions.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder in shallow end >6" from wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed several chips on deck in need of repair. .2537(2) Decks shall be kept in good repair.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed pressure gauge not reading correctly on filter. Corrected during inspection. .2519(k) Provide operational pressure gauge on filter.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed urinal not functioning in restroom. .2526(f) At least one sink, one toilet, one urinal is required for men's restroom.