Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameQUAIL HOLLOW COUNTRY CLUB
Address3700 GLENEAGLES RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/18/2017
Final Score @ Grade
32
General Comments6 - General Comment - Observed aerator pump , Pentair WFE-2 pump, tied to (2) Waterway 640-231x drain covers. No PDSC form submitted. Submit within 3 days or permit will be suspended. 15 - General Comment - Both ring buoys on deck with grab rope degraded. Replace with USCG approved ring buoys within 30 days. 21 - General Comment - Pool hours not posted. If night swimming, provide at least 10 ft candles on deck and lights in pool must be operational. 22 - General Comment - Dialing instructions not clearly visible. Re-post instructions. Emergency phone location not clearly visible on all areas of pool deck. Provide additional signage within 30 days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain checks not recorded regularly. Record daily. Acid and alkalinity not recorded. Record weekly. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching and staining on pool floor. Keep in good repair.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Wall depth marker missing numbers at 8 ft 6 in. Replace on wall. Intent to Suspend issued. Damage to one deck no diving marker. Replace. Intent to Suspend issued. Wall depth marker at step entry - 4 ft not legible. Replace. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No No labeling on diving platflorm. A label shall be permanently affixed to the equipment and shall include 1) Mfg name and address; 2) board length; 3) type of board; 4) fulcrum setting.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No One body hook not attached to pole. Corrected during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates on to pool deck with 37" between horizontals. Pool built prior to 2010. Observed railing outside of back entrance gate at 42" in height. Eliminate foothold. Pool built prior to 2010. Observed 37" between horizontals on fencing surrounding pool. Provide at least 45" between horizontals. Pool built prior to 2010. Doors on to deck not made to self-latch - doors have latching mechanism that was not engaged. Corrected during inspection. Doors shall remain self-closing, self-latching.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck damage at pillar by entry to wading pool. Eliminate hazard to public. Intent to Suspend issued. Damage to deck drain in several locations including at deep end of pool and along perimeter close to wading pool. Repair deck drain as needed. Intent to Suspend issued. Jagged edges at depth markers in several locations. Repair edges of deck where needed along perimeter of pool. Intent to suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room left unlocked. Keep locked to keep inaccessible to the public.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in restrooms >110 F. Maintain at 110 F or below.