Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWEATHERSTONE
Address10140 TREE TOP LN
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/11/2016
Final Score @ Grade
32
General Comments15) Ring buoys and throw ropes worn. Recommend replacing with US Coast Guard approved ring buoy and 50 foot throw rope. Pool needs 2 sets of ring buoys. 16) One gate broken during inspection. Will use other gate until it is fixed. Permit will be issued at Meckpools.charmeck.org. Print copy of permit to post in the pool area.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. Corrected to 7.2.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form does not match what was installed. New 4HP equalizer line covers installed. Udated PDSC form submitted and approved.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. Vacuum the pool floor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir not installed correctly. Corrected by operator.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One inlet fitting missing. Corrected by operator.
22 6 Premises: emergency telephone provided No No No Emergency phone number does not match what 911 has. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in pump room not working. Fix fan.