9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed several depth markers missing, Replace
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gap in gate 1" between gate and fence within 18" of the unlatch mechanism.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed no sign with dialing instructions, address or telephone number at emergency phone.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic feeder does not have display functioning for controls.
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed pump different from previously submitted PDSC form. WFE 12 on file IntelliFlo 3 present.
.2518(h) Provide approved pump in good repair.
Observed flow meter not functioning.
.2518(g) Keep flow meter operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Store in chemical closet.
Observed mechanical ventilation not functioning in chemical storage room.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Urinal in mens room not functioning.
.2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. |