| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Cl @ .2. Cl tablets in skimmer baskets & none in chlorinator. ** Do not put chlorine tablets in skimmer baskets ever. Maintain Cl @ at least 1ppm via properly operating chlorinator. Chlorine level could not be raised while EHS on-site. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No pool records. ** Maintain complete pool records. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae on pool floor & walls. ** Rectify & clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
1 weir missing. ** Install. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders >6" from pool wall. ** Maintain from 3" to 6".1 ladder handrail not secured to deck, is missing first step, screw still in place & no end caps. ** Correct. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
No throw rope. Ring buoy split & dry rotted. ** Ring buoy replaced & new throw rope tied to new ring buoy. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Furniture as close as 3.5' from pool edge. ** Maintain 6'. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter float stuck. ** Keep operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No natural cross draft or forced air vent (operable) in equipment/ chemical room. ** Provide. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash pipe inserted down into sump. ** Provide complete air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Feces on toilet seat in womens' restroom. ** Clean.No soap in mens' or womens' restrooms. ** Provide soap. |