Premises Information

Return to Inspections
NameAUREA STATION APARTMENTS
Address8625 WINTER OAKS LANE
AUREA STATION APARTMENTS
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/20/2025
Final Score @ Grade
16
General CommentsEHS recommends replacing the “Warning No Lifeguard On Duty” sign before next season due to it fading. EHS has verified that color band tiles have been replaced and the pool deck has been repaired/painted. Inspection completed with CPO, Tony Jones All permit compliance items corrected during inspection Interlock tested and operational CPO log records begin today NIGHT SWIMMING NOT ALLOWED Permit Restriction - Flow Meter MUST remain operable. Flow shall be close to 98gpm as possible. Flow does not meet turnover. If clarity is an issue, a filter change may be required. Permit issued

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed a 50ft rope on the ring buoy. CDI - Rope was cut to 36 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Gate latches shall be 54" in height. Observed a broken top latch to the gate. Gate was not self closing due to one spring missing. CDI - Employees installed a new 54” top latch to the gate and replaced the missing spring. Gate is now self closing and self latching with a 54” tall top latch.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed no working flow meter. CDI - Employees were able to get it unstuck to where it was reading 35gpm. After backwashing the filters, flow meter came up to 98gmp. .2518(e) Provide a spare basket for pump. Observed missing spare basket for the pump.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Observed no hose bib available within 50 feet.