Return to Inspections
NameAPPLEGATE
Address5218 JEWELFLOWER RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/11/2023
Final Score @ Grade
18
General CommentsNight swimming is not approved.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. - Observed pool floor and surface with debris. CDI- CPO started to clean during the inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.- Observed minor debris and rocks in skimmer baskets. CDI- CPO removed items form skimmer baskets.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. - Observed front gate malfunctioning at the start of the inspection to no self close. CDI- CPO made some adjustments to gate and EHS observed front gate self closing and self latching.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. - Observed flow meter malfunctioning during the inspection. CDI- PIC made some adjustments and EHS observed flow at 250 gpm.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed hose bib being used to fill pool water without a proper back flow prevention device.