Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEASTOVER RIDGE
Address3300 EASTOVER RIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/5/2026
Final Score @ Grade
24
General CommentsInspection conducted with CPO, Robert Frilot. Permit issued. Repairs to deck have been made, as required. No gaps in deck observed. Water chemistry and emergency phone signage corrected during inspection. Night swimming not allowed. Door onto pool deck from club house near women’s restroom must be self closing and self locking within 30 days or permit will be suspended. In the meantime, door shall remain locked. Call EHS to arrange visit once repaired.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8 upon start of inspection. Corrected- CPO raises pH to 7.2 with soda ash.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed leaf litter and debris in water. View of drain covers and suction outlets not obfuscated. Correction in process- vacuum placed into water.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed leaf litter inside multiple skimmer baskets.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed door onto pool deck from inside club house near women’s restroom not self-closing.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no signage indicating pool address at emergency phone. Corrected- CPO posts legible sign with phone number and address at emergency phone.