Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEASTOVER RIDGE
Address3300 EASTOVER RIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/7/2024
Final Score @ Grade
22
General CommentsNo Night swimming Per conversation with C. Sells: <45” Between horizontals on gate. Requires repair prior to permit 2025.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace damaged skimmer lid. Observed damaged skimmer lid near fountain. Damage is minor chipping, and not of injury concern. CDI: CPO has ordered new lid but it has not yet arrived.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed end caps missing on one ladder. REPEAT VIOLATION
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope longer than 24’. CDI: Rope cut to 24’ during inspection. REPEAT VIOLATION
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches shall be 54" in height. Observed gate latch at 48”. CDI: Gate latch moved up to 54”. .2528(b) Horizontals shall not be located less than 45" in height. Observed gate horizontal is 36” on 4 decorative gates that lead to apartments. Pool is built pre-2010. Per conversation with C. Sells: <45” Between horizontals on gate. Requires repair prior to permit 2025.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed minor damage to deck near grills, toward right side of the pool, and near left side of pool near where deck sections come together. Have deck area filled to be smooth.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash. REPEAT VIOLATION