Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRADITION AT MALLARD CREEK
Address2525 CRESCENT VIEW DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/24/2026
Final Score @ Grade
12
General CommentsPERMIT RESTRICTIONS: - Flow meter must remain operable. Flow not to exceed 252 GPM due to equalizer line cover flow restriction. Suction Hazard. - Night Swimming is NOT permitted. NOTE: - There is a full 16” of straight run pipe before the flow meter on one side and about 20” straight run pipe on the other side before the flow meter. - CPO: Myron Grimes present during permit inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread.- Observed two ladders one on each end of the pool. One ladder is missing slip resistant tread on a middle step. The other one missing last two steps. Replace the slip resistant treads on ladders.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.- Observed the rope length measured at 47 ft. Item replace to be at 50 ft during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.- Observed windows in the clubhouse leading out to pool deck have the ability to open all the way up. Items fixed to be permanently closed, not able to open at the time of inspection.