8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. 2 Weirs missing, replaced during inspection. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed four depth markers on pool deck missing "FT" symbol.
PO made temporary fix by permanent marker. Have tiles corrected or replaced by next pool season. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. One pool ladder missing safety end caps. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
Pool safety signs not posted. PO provided proper signage. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency phone sign not posted at phone. PO posted proper emergency phone sign. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room exhaust fan not operating.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Hose bibs in pump room need backflow prevention devices. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2626(h) Shower(s) shall be provided. Showers were being renovated and were un-usable at time of inspection.
GENERAL COMMENT: Permit issued. Permit condition: Flow must not exceed 282 GPM. |