Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRIVIERA
Address12020 VALLEY OAK ST
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/23/2020
Final Score @ Grade
18
General CommentsSkimmer equalizer covers expire October 2020. Replace and submit updated PDSC information for approval prior to expiration of covers. Permit will be suspended if covers are not approved and replaced prior to expiration. No Night Swimming. Changed to "A" Open for Business, valid permit, with condition of staying closed to public by Executive Order-120, or other Orders, outlined in permit. Operator unable to sign due to COVID-19 protocol and safety precautions to not share equipment. Inspection completed with: Mark Houff Sent report to: inspections@tridentpoolgroup.com

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced. Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New buoy rope at time of inspection. Too long. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 45'.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Horizontal from brick wall on side of fence, less than 45" in height. Fence bowed in some areas, greater than 4" gaps. Pool built pre-2010. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals for feeder in pump room. Chemical storage room being used for pool storage rather than chemicals. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in women's restroom at time of inspection. Provide paper towels/hand drying for handwashing.