2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm.- Observed chlorine measured at 0.4 ppm. Ensure to maintain at least 1.0 ppm of chlorine in the pool through automatic chlorinator.
NOTE:
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.- Observed pH is less than 6.8. Ensure to maintain pH between 7.2- 7.8 at all time. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
NOTE:
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.- Observed the reagent #2 is expiring soon (6/2025). Ensure to obtain and provide up to date chemical reagents for testing during and through out 2025 pool season. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.- Observed one of the vacuum port left opened/un covered. CDI- a port was covered and capped at the time of inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace damaged skimmer lid.- Observed one damaged skimmer lid. Need replacement. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times.- Observed chairs on narrow path of pool deck measured less than 6ft from edge of the pool. CDI- items removed from the path and place on the open side of the pool deck at the time of inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2519(k) Provide operational pressure gauge on filter.- Observed one of the pressure gauge of sand filter is not working. Repair/replace needed. |