Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGREENWAY AT MALLARD CREEK
Address8230 GREENWAY VILLAGE DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/15/2023
Final Score @ Grade
26
General CommentsPre-permit inspection conducted with James Rabon. Like for like change of pool pump and motor. No record that electrical permit and inspection have been obtained from Mecklenburg County Code Enforcement. - G.S. 130A-2(3) Ensure all electrical work is completed by a licensed electrician and electrical permit and passing inspection are obtained from Code Enforcement. - Pre-permit item. Pre-permit inspection did not pass 5, 6, 9, 16, 17, Electrical permit. There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Have no CPO on file for this pool. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Pool recently replastered. Looks like VGB2008 A10RCFRxxx covers installed without a riser ring. Covers expire 10-1-2023. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Pre-permit item. Equalizer line covers appear to be plugged per state recommendations. Provide updated PDSC form. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No One section of depth markers and tiles covered with painters tape. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Corrected. Some depth markers on pool wall are different than what is listed on pool deck. .2523(a) Provide depth markers on pool walls and pool deck to denote the water depth. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Manga-latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Pre-permit item. Magnetic latch < 45” high, creating a foothold at main gate. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Two windows from office to the pool deck capable of opening all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Hole in the deck where fill spout was. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash piping for one of the filters extends into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One faucet not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.