Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMONTEITH PARK
Address15245 WATERFRONT DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/13/2017
Final Score @ Grade
32
General CommentsPDSC form states that waterslide pump is a 10HP Berkeley B3ZPM5 pump. Observed 7.5 HP motor on pump, pump data plate no longer legible. Recommend verifying pump and that motor isn't undersized. Permit posted in office. Post permit such that it is easily visible by pool bathers. Intent to suspend issued. 5) 16) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. Maintain between 7.2 and 7.8. Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Only one TA and CYA check for the last month. Check at least daily Cl, pH, main drains and at least weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Very little flow in all skimmers. Ensure proper pool turnover and that skimmers function correctly. Some weirs missing. Install functional weirs. Some skimmer baskets damaged. Maintain in good condition.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladders loose and/or missing non-slip treads. Maintain secure and in good condition.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates < 48" in height. Provide fencing that meets requirement in .2528, including at least 48" high, no gaps > 4", latch height of 54" or use keyfob, and open away from the pool. If new gate is installed gate must have at least 45" between horizontals. - Intent to suspend item. Windows opening onto the pool deck shall be self-closing or child protected or not capable of opening > 4" inches. - Intent to suspend item. Most of fence < 48". Maintain fence at least 48" high.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chairs too close to pool edge. Maintain at least 8 feet clear walkway. - intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pump motor grounded to wading pool, not to main pool. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No One filter leaking. Fix leak. Some chemicals stored in pump room. Store all chemicals in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.