15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope length for ring buoy required at 30’. EHS observed rope length at 24’ during inspection. CDI - Operator installed new rope at 30’. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Horizontals shall not be located less than 45" in height. EHS observed potential foothold with brick walling around building that wraps between building and fence. The height of the brick wall is 33” from ground level, 4” offset from wall. EHS observed distance between horizontals at 35”. Fence was built pre-2010. |