| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Equalizer lines not plugged in the skimmers. .2518(k) Skimmer equalizer lines shall be in compliance with ANSI/PHTA/ICC-7 or disabled. - Pre-permit item.
Missing one weir. .2518(k) Replace missing weirs. - Pre-permit item.
Three skimmer baskets cracked or broken. .2518(k) Replace missing or damaged skimmer basket. - Pre-permit item. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Facility with only one body hook and one ring buoy. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. - Pre-permit item.
Throw rope not a continuous rope. .2530(a) Provide US Coast Guard approved ring buoy with attached 50 foot throw rope. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both gates swing in towards the pool. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item.
Exterior window in pump room capable of opening all the way. .2528(a) Ground level windows shall not open greater than 4". - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs and table too close to the pool. .2522(a) Provide 8 ft of clear walking space around the outdoor pool at all times (>1600 sq. ft). - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect dialing instructions posted on emergency phone sign. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Piping for main drain not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Out of toilet paper in both restrooms. .2526(l) Provide toilet paper and dispensers in restrooms. |