Premises Information

Return to Inspections
NameCARRINGTON RIDGE
Address6865 COLONIAL GARDEN DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/31/2024
Final Score @ Grade
48
General CommentsReturn visit will be made in one week to verify repair to the step handrails, replacement of weirs, and repair to the gate. Pool installed new deck without permits. Referred to Code Enforcement. PC with Code Manager during inspection. Permits will be required with sealed plans. New barrier installed along back side of the barrier along deck. Fence at least 48" from ground on outside with 45" between horizontals. 4" or less between pickets. 2" or less underneath. Will require a permit final prior to 2025 operating permit. Matt Yates present during the inspection. Permit issued for no night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Staining and some debris on pool surface. May require repair in future if worsens. Pool plaster shall reflect greater than 50% of light.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No (3) of 10 weirs missing. Replace weirs. Given one week to correct.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both step handrails loose. One handrail missing bolt. Hole plastered over. Given one week to correct both handrails.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Both ring buoy ropes greater than 50 ft. Cut to 50 ft. during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main entry gate with horizontals <45" apart. Maintain 45" between horizontals. Given one week to correct.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Opening in deck with anchor. Plugged during the inspection to eliminate opening.
18 4 Premises: lifeguards present or warning signs posted No No No Warning signage missing from pool deck. Corrected during the inspection.
22 6 Premises: emergency telephone provided No No No Phone not visible from all areas of the pool deck. Pool rules sign - location written on to sign.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automated feeder disconnected. Not detecting flow. Using 300-29x. Not approved for pool size. 300-29x only approved for up to 57,000 gallons. Pool size is 124,000 gallons. Operator switched feeder from the wading pool to the main pool during the inspection. 300-29x chlorinator not installed per mfg. instructions. Install per NSF requirement with flow meter.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Leak at pipe leading from pump to the filter. Repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights burnt out in chemical storage room and some in pump room. Provide lighting/repair.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One soap dispenser not operable in women's restroom. Keep operable. Toilets with some build-up. Keep clean.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in pump room and in restrooms without backflow prevention device. Provide backflow prevention devices on hose bibs.