Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA QUINTA INN & SUITES
Address4900 S TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/28/2023
Final Score @ Grade
14
General CommentsIssued permit. No Night Swimming. NOTE: Main drains expire in 2024. Update and submit PDSC form for approval for 2024 for permit. Inspection with Maria Trejo

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinity and cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator took readings and recorded. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-closing, self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected. Fence horizontals less than 45” in height. Original construction. .2528(b) Horizontals shall not be located less than 45" in height.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3’ clear walking space around equipment. Pool built ‘98. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 100 F in restroom and one toilet out of order in women’s restroom. No paper towels in restrooms. .2526(i) Water in restrooms shall not exceed 110 F. .2526(m) Keep restrooms and fixtures clean and in good repair.