General CommentsCall mainline 980-314-1620 to pay $100 revisit fee, pool ID 501040. Correct *permit items from pre-permit inspection and contact Marie Daley for pre-permit inspection when ALL permit items are in compliance for inspection at 704-507-6806. Pool MUST REMAIN CLOSED until inspection passed and permit received. Q Permit Denial Inspection with Maria Trajo

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Skimmer equalizer covers have outer old rings, but plugged in middle/inside. PDSC form shows A10RCFR. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. *Permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-closing, self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item Fence horizontals less than 45” in height. Original construction. .2528(b) Horizontals shall not be located less than 45" in height.
22 6 Premises: emergency telephone provided No No No Emergency phone signage does not include dialing instructions. Phone rings back to main desk, but staff did not see emergency call made out or able to direct back to emergency phone at pool location. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. *Permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Inlet fitting missing. .2518(i) Arrange inlets to produce uniform circulation. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 100 F in restroom and one toilet out of order in women’s restroom. .2526(i) Water in restrooms shall not exceed 110 F. .2526(m) Keep restrooms and fixtures clean and in good repair.