Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARBOR STEELE CREEK
Address12235 STONE ARBOR WY
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/17/2020
Final Score @ Grade
20
General Comments23 - Chlorinator not installed with flow meter. Install per mfg. instructions. Original installation. Note: No fresh air intake in pump room with forced draw ventilation. Permit issued for no night swimming. Santiago Hernandez present during the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log book not maintained. Pool has been closed. Log book provided during site visit. Ensure daily record keeping for chlorine, pH and main drain checks. Record total alkalinity and cyanuric acid weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing weirs in skimmers (2) of four. Operator had purchased but not yet installed. Replace skimmer weirs.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing - Pool built prior to 2010. - Pool fence <48" in height. Maintain 48" in height. - Gas tank and HVAC unit located within 45" of barrier. Eliminate footholds.
22 6 Premises: emergency telephone provided No No No Phone number listed did not match 911. When called number back that 911 had, called emergency phone. Listed phone number at phone struck through and new phone number posted during inspection.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap above pit.