5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Main drain checks not recorded. Record daily. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two weirs sticking. Keep operational. 6 skimmers present. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Wall depth markers missing feet or ft. Provide on all wall depth markers. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Step handrail loose. Ladder handrails >6" from pool wall. Pool constructed with ladders as is. Keep all handrails tight and maintain handrails between 3' and 6" from pool wall. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Signage not correct wording or size. Provide "Adults should not swim alone." and "Children should not use the swimming pool without adult supervision." in 1" lettering including lowercase lettering. Intent to Suspend issued. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
911 operator indicated that she could not hear inspector during inspection. Corrected during the inspection. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower not operable. Repair. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restrooms >120 F. Maintain at 110 F or below.
Two toilets in women's restroom not operating. Repair. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib in pump room before check valve. Provide backflow prevention device on all hose bibs. |