Premises Information

Return to Inspections
NameCALDWELL STATION
Address17320 CALDWELL RUSH CR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/5/2026
Final Score @ Grade
22
General CommentsInspection conducted with Eric White. All issues corrected by end of inspection. EHS strongly recommends having emergency phone and phone line evaluated. Permit will not be issued for 2027 season if emergency phone operation is not consistent. Permit Restriction: Flow meter must remain operable with flow set 384-423 GPM. No night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2537(7) Drain covers shall be in good condition and securely attached. Observed equalizer cover in shallow area detached. Operator replaced during inspection.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing return fitting covers and/or eyeball fittings in 3’ and 5’ depth areas of pool. Replace.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Observed chairs within 3’ of pool edge. Corrected.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Upon arrival emergency phone inoperable. Phone repaired, however, observed to be inconsistent. Phone must remain fully operable at all times. Corrected during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed chemicals and chairs/equipment stored in pump room.