Inspection Date 4/18/2019
Final Score @ Grade
18
General CommentsPer PDSC forms pump listed as Pentair EQ 750. Pump model on data plate Pentair EQKT 1000 / 340606. Per note listed on last seasons inspection, in field review completed. The findings and approval are as follows: Pump data plate is Pentair EQKT1000. Motor is 7.5 HP. Pump was broken down and impellar inspected. Part # on impellar is 350029. Pentair document indicates 350029 is compatible with 7.5 HP pump. During inspection confirmed pump model, main drains covers Aquastar 1216xxx; and equalizer covers Aquastar 4 HP. Also confirmed pipe diameter for drains (6", 6", 4") skimmers, and return; Filter TR140C (3) GENERAL COMMENT: .2537(2) Decks shall be kept in good repair. Pool decking at ladder on side closest to wading pool damaged. Repair. Ensure permit remains visible at all times. Night swimming is not permitted at this pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Initial testing of pH found to be at 7.0. CDI- CPO AJ was able to correct. pH at 7.2 when tested after correction.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder on the side closest to wading pool loose. CDI- CPO repaired.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Both ropes attached to both ring buoys greater than the required 50Ft. CDI- CPO corrected both.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Enclosed electrical outlet boxes and supports around perimeter of fencing of the pool creating foot holds and decreasing required spacing of 45" for pool installed pre-2010. Provide sheathing or method to inhibit foot hold.