Return to Inspections
NameCAMDEN SOUTH END
Address1205 S. TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/15/2024
Final Score @ Grade
20
General CommentsCPO, Pete McKenzie present during the inspection. Night swimming prohibited. Verified: Permit Restriction - Flow meter must remain operable. Flow shall be set at 69 gpm to 80 gpm to meet turnover and flow restriction of number of returns. New Pump Pentair Intelliflo3 011077, 3 hp pump. (2) Aquastar A10RCFRxxx VGBA-2017 drain covers. FlowVis flow meter installed reading above permit flow restriction (same as submitted picture). (1) Pentair TR100 C filter 4 returns 3 skimmers Main drain, skimmer and return line all 2” pipe through the floor of the pump room. EQ lines are plugged. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmers. CDI - CPO cleaned.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy was too long, CDI - CPO shorten the rope to required length of 32’
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Window’s in the community room open fully. CDI - CPO added screws to prevent opening more than 4”.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Lounge chairs obstructing clearance around the deck at less than 6’. CDI - CPO relocated chairs
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed hose bib on the pool deck without a backflow preventer. Provide.