Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Initial pH reading of 7.0. CDI- CPO was able to correct pH to 7.6. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Electrical box and support located on the fence exterior closest to the parking lot creating a foothold and reducing the required 45" between horizontals. Pool is pre-2010, and will be allowed to operate per regulations. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Automatic feeder did shut off when power to pump was turned off, but did not come back on when power was returned to the pump. CDI- CPO was able to repair issue, and able to speak with someone about re-checking all electrical systems for the pump. |