Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PERMIT RESTRICTION - PUMP MUST RUN AT MANUFACTUER SET SPEED OF SPEED 4 - 3110 RPM. FLOW METER MUST REMAIN OPERABLE AT 60 GPM - TDH PROVIDED. EHS unable to verify pump was locked and set at speed 4 - 3110 rpm due to inoperable digital plate on pump that shows speed and rpm. Repair. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool and on pool floor. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 57 feet. CDI, throw rope adjusted to 50 feet. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Observed electrical issue per operator not allowing automatic chlorine feeder system to pump chlorine. Pump tested by pool operator on site. EHS and operator unable to verify system working properly and pump / motor not functioning on disinfectant side. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap at handwashing sink in restroom. |