Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBENNINGTON PLACE II
Address15065 DESHLER CT
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/9/2020
Final Score @ Grade
22
General CommentsPump must run at manufacture set speed of Speed 4 No Night Swimming. Changed to "A" Open for Business, valid permit, with condition of staying closed to public by Executive Order-120, or other Orders, outlined in permit. Operator unable to sign due to COVID-19 protocol and safety precautions to not share equipment.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records for pool at time of visit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator filled out records. Corrected.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No "FT" missing from 4 1/2 FT tile, leaving greater than 25' between depth markers. .2523(c) Depth markers shall include the word "feet" or symbol "ft". .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum port fitting replaced and protruding from wall more than 2 inches. .2518(i) Provide inlet fittings in good repair. Operator replaced with plug, flush with wall. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in equipment room. Pool built '03. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink.