3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.- Observed pH measured 7.0, fixed during the inspection to 7.2 |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.- Observed missing cap/cover , one of the vacuum holes on pool wall. Fixed during inspection, putting cap to close/cover the hole. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.- Observed missing screws on one of the pool floor return cover. Fixed during the inspection. Screwed all tight and in placed. |