8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
(.2518, .2537)- Observed rocks inside 50% of skimmers. CDI- CPO removed rocks. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
(.2517, .2521)- Observed ladder on 4ft side with a missing cap and several ladders/rails in need of tightening down around the pool since they are loose. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
(.2528, .2537)- Observed horizontal foot hold 35-38 inches on out side of fence from another foot hold. Brick wall meeting fence horizontal bar is 35-38 inches. Pool constructed in 2002. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
(.2512)- Observed hose bib on pool deck without a proper back flow prevention device. Provide.
CPO Danny Richards was present during the inspection.
Meck county permit number: 18-601069 |