Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHERITAGE GREEN
Address19055 LONG POND LN
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/17/2024
Final Score @ Grade
18
General CommentsPERMIT RESTRICTIONS: - Flow meter must read at 360 GPM no greater that 460 GPM due to drain cover restrictions. - Today flow read at 375 GPM during visit. NOTE: - This pool # 500993, permit denied today due to the following items on the inspection sheet. - All items needs to be repaired/replaced, and ensure it is in good working condition. - Contact EHS: 704-617-9777 or email for return inspection to obtain the operational permit. - The pool shall remain closed until permit is issued. - Return visit fee is $100. Need to be paid through the office: 980-314-1620 prior to inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.- Observed 4 missing equalizer covers out of 12 totals. Need replacement.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs.- Observed two missing weirs out of twelves total.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.- Observed 2 missing return line covers. Need replacement. .2537(10) Diving equipment and pool slides including stairs and railings shall be kept in good working order.- Observed one disrepair stair. In the process of fixing. Keep in good working order.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching.- Observed back gate “Exit only” sign posted. It is magnetic gate, it will come close to magnet when swing open, and depending on direction and way, it may latch completely. And this case it doesn’t latch more than half of the time. It didn’t close completely as it should, left access to the pool. This gate shall be repaired and ensure it works properly in timely manner.