Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.387. EHS observed that one of the equalizer covers was missing during the inspection. CDI- CPO was able o install the same equalizer cover that is referenced on the PDSC form. Facility will use the expiration date of 05/09/2029 for all 11 equalizer covers.
-6- |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. EHS observed less than 3 ft. Walking space around equipment in pump room.
-2-
.2533(b) Provide sufficient lighting in pump room. |