Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameREEDY CREEK
Address8311 REEDY CLUBHOUSE RD
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/21/2026
Final Score @ Grade
24
General CommentsNight Swimming is NOT permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on floor of pool.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed two (2) of eleven skimmers with missing weirs. Observed minor debris build up in skimmer baskets.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed four (4) return inlets with missing eyeball fittings. CDI - CPO attached replacement fittings to returns.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed one (1) of two provided body hooks not attached to pole. CDI - CPO attached body hooks to pole via two bolts with wing nuts. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed two (2) ring buoys with damaged ropes of less than the required 50 ft. CDI - CPO attached new ropes to ring buoys, measured them to 50 ft, and cut them to length accordingly.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed two (2) clubhouse doors with no audible alarms. CDI - CPOs attached alarms to doors.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed four (4) bottles of liquid muriatic acid stored on top of unopened boxes of granular chlorine. CDI - CPO moved bottled chemicals to separate location.