NameMACAULAY
Address16023 HALLATON DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2025
Final Score @ Grade
20
General CommentsPermit denied due to: -Pump not grounded properly -water murky and unable to visibly see main drains - automatic chlorine feeder not able to turn off when pump it turned off. PERMIT DENIED. FLOW METER READING: 320 Below are the current comments and permit restrictions for the pool/spa referenced above: Permit Restriction: Flow meter must remain operable. Flow shall not exceed 500 gpm due to drain cover flow restriction. NIGHT SWIMMING WILL NEED TO BE APPROVED AFTER A NIGHT VISIT TO CONFIRM LIGHTING IS SUFFICIENT.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No .2535(2) Main drains must be clearly visible from the pool deck. Observed pool water murky and main drains not clearly visible. Permit denial.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed moderate debris in bottom of pool.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed automatic chlorine feeder unable to stop operation when circulation pump was turned off. CPO stated that he will have an electrician address this issue before next inspection. Permit denial.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(h) Provide approved pump in good repair. Observed pump not properly grounded. Grounding wire was not attached to bonding wire creating an electrical hazard. CPO was instructed to have an electrician repair and address this issue before next inspection. Permit Denial.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Post a shower sign visible upon entrance to the pool. Observed no “shower sign” present on pool deck. CDI: CPO installed a shower sign.