Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLAWYERS RIDGE APARTMENTS
Address5310 MCALPINE GLEN DR
 
City/State/ZIP
CHARLOTTE NC 28227
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/28/2025
Final Score @ Grade
32
General CommentsCall Main Office at 980-314-1620 to schedule re-inspection. Re-inspection fee of 100$ required.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.8ppm. Permit denial issued
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.1. Permit denial issued
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit without cyanuric acid testing reagent. Permit denial issued.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 30ft. Observed ring buoy small grab rope rip off ring buoy when picked up. Permit denial issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches shall be 54" in height. Observed latching mechanism on gate closest to pump room only 46 inches from ground. Permit denial issued. .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate closest to pump room NOT self closing, self latching. Permit denial issued.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed phone able to connect to 911. Observed phone unable to ring back when called. Permit denial issued.