Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameKINGSTREE
Address7701 PAPER BIRCH DRIVE
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/16/2023
Final Score @ Grade
8
General CommentsObserved greater than 50 of fence removed and replaced. All fencing must come up to post 2010 requirements. Observed gate to pool with foothold from magnet, 35” between horizontals. Observed gate to pool with gap under greater than 2”. Observed fence in gazebo area with 4” gaps underneath and greater than 4” between wood post and metal pickets. Observed wading pool gate swinging toward pool. Observed baby pool fence between pool and wading pool with less than 45” between horizontals. Observed wading pool fence height at 46”. Observed light transformer box presenting foothold, less than 45”. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). .2528(a) Provide no openings in fence and/or gate greater than 4"x4". .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). .2528(c) New fencing installed must be in compliance with .2528 Fences. .2531(a) Wading pool gates shall open away from the swimming pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed greater than 50 of fence removed and replaced. All fencing must come up to post 2010 requirements. Observed gate to pool with foothold from magnet, only 35” between horizontals. Observed gate to pool with gap under greater than 2”. Observed fence in gazebo area with 4” gaps underneath and greater than 4” between wood post and metal pickets. Observed wading pool gate swinging toward pool. Observed baby pool fence between pool and wading pool with less than 45” between horizontals. Observed wading pool fence height at 46” Observed light transformer box presenting foothold, less than 45”. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). .2528(a) Provide no openings in fence and/or gate greater than 4"x4". .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). .2528(c) New fencing installed must be in compliance with .2528 Fences. .2531(a) Wading pool gates shall open away from the swimming pool.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed fill spout hole not covered. Observed chips around several skimmer lids. Observed skimmer collars not flush at 4’ on right and on left and right at 5’ on side. Observed holes for backstroke poles greater than 1/2”. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.